AF12-30-10-13-DC Power Contactor

SKU: 1252602683 Categories: , Tag:

Extended Product Type 

AF12-30-10-13

Product ID

1SBL157001R1310

EAN 

3471523110335

 Description

  • The AF12-30-10-13 is a 3 pole – 690 V IEC or 600 UL contactor with 1 built-in auxiliary
    contact and screw terminals.
  • controlling motors up to 5.5 kW / 400 V AC (AC-3) or 7-
    1/2 hp / 480 V UL and switching power circuits up to 28 A (AC-1) or 28 A UL general
    use.
  • Thanks to the AF technology, the contactor has a wide control voltage range (100-
    250 V 50/60 Hz and DC).
  • managing large control voltage variations, reducing panel
    energy consumption, and ensuring distinct operations in unstable networks.
  • Furthermore, surge protection is built-in, offering a compact solution.
  • AF contactors have a block-type design and can be easily extended with add-on auxiliary contact blocks
    and an additional wide range of accessories.

 

Dimensions

  • Product Net Width:  45 mm
  • Product Net Depth / Length: 77 mm
  • Product Net Height: 86 mm
  • Product Net Weight: 0.27 kg

 

 

 

 

 

Request for quote

Technical

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    0
  • Standards:
    IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
  • Rated Operational Voltage:
     Auxiliary Circuit 690 V
    Main Circuit 690 V
  • Rated Frequency (f):
     Auxiliary Circuit 50 / 60 Hz
    Main Circuit 50 / 60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A
    acc. to IEC 60947-5-1, q = 40 °C 16 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 40 °C 28 A
    (690 V) 60 °C 28 A
    (690 V) 70 °C 24 A
  • Rated Operational Current AC-3 (Ie):
    (415 V) 60 °C 12 A
    (440 V) 60 °C 12 A
    (500 V) 60 °C 12.5 A
    (690 V) 60 °C 9 A
    (380 / 400 V) 60 °C 12 A
    (220 / 230 / 240 V) 60 °C 12 A
  • Rated Operational Current AC-3e (Ie):
    (415 V) 60 °C 12 A
    (440 V) 60 °C 12 A
    (500 V) 60 °C 12.5 A
    (690 V) 60 °C 9 A
    (380 / 400 V) 60 °C 12 A
    (220 / 230 / 240 V) 60 °C 12 A
  • Rated Operational Power AC-3 (Pe):
    (400 V) 5.5 kW
    (415 V) 5.5 kW
    (440 V) 5.5 kW
    (500 V) 7.5 kW
    (690 V) 7.5 kW
    (380 / 400 V) 5.5 kW
    (220 / 230 / 240 V) 3 kW
  • Rated Operational Power AC-3e (Pe):
    (415 V) 5.5 kW
    (440 V) 5.5 kW
    (500 V) 7.5 kW
    (690 V) 7.5 kW
    (380 / 400 V) 5.5 kW
    (220 / 230 / 240 V) 3 kW
  • Rated Operational Current AC-15 (Ie):
    (500 V) 2 A
    (690 V) 2 A
    (24 / 127 V) 6 A
    (220 / 240 V) 4 A
    (400 / 440 V) 3 A
  • Rated Short-time Withstand Current Low Voltage (Icw):
     at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State, 1 s 300 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State, 30 s 80 A
    for 0.1 s 140 A
    for 1 s 100 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
  • Maximum Electrical Switching Frequency:
    (AC-1) 600 cycles per hour
    (AC-15) 1200 cycles per hour
    (AC-2 / AC-4) 300 cycles per hour
    (AC-3) 1200 cycles per hour
    (DC-13) 900 cycles per hour
  • Rated Operational Current DC-13 (Ie):
    (24 V) 6 A / 144 W
    (48 V) 2.8 A / 134 W
    (72 V) 1 A / 72 W
    (110 V) 0.55 A / 60 W
    (125 V) 0.55 A / 69 W
    (220 V) 0.27 A / 60 W
    (250 V) 0.27 A / 68 W
    (400 V) 0.15 A / 60 W
    (500 V) 0.13 A / 65 W
    (600 V) 0.1 A / 60 W
  • Rated Insulation Voltage (Ui):
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
    acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Up):
    6 kV
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Rated Control Circuit Voltage (Uc):
    50 Hz 100 … 250 V
    60 Hz 100 … 250 V
    DC Operation 100 … 250 V
  • Operate Time:
     Between Coil De-energization and NC Contact Closing 13 … 98 ms
    Between Coil De-energization and NO Contact Opening 11 … 95 ms
    Between Coil Energization and NC Contact Opening 38 … 90 ms
    Between Coil Energization and NO Contact Closing 40 … 95 ms
  • Mounting on DIN Rail:
     TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
    TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Mounting by Screws (not supplied):
    2 x M4 screws placed diagonally
  • Connecting Capacity Main Circuit:
     Flexible with Ferrule 1/2x 0.75 … 6 mm²
    Flexible with Insulated Ferrule 1x 0.75 … 4 mm²
    Flexible with Insulated Ferrule 2x 0.75 … 2.5 mm²
    Rigid 1/2x 1 … 6 mm²
  • Connecting Capacity Auxiliary Circuit:
     Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
    Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²
    Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²
    Rigid 1/2x 1 … 2.5 mm²
  • Connecting Capacity Control Circuit:
     Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
    Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²
    Flexible with Insulated Ferrule 2x 0.75 … 1.5 mm²
    Rigid 1/2x 1 … 2.5 mm²
  • Wire Stripping Length:
     Auxiliary Circuit 10 mm
    Control Circuit 10 mm
    Main Circuit 10 mm
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
  • Terminal Type:
     Screw Terminals

Technical UL/CSA

  • NEMA Size:
    0
  • Continuous Current Rating NEMA:
    18 A
  • Horsepower Rating NEMA:
    (115 V AC) Single Phase 1 Hp
    (200 V AC) Three Phase 3 Hp
    (230 V AC) Single Phase 2 Hp
    (230 V AC) Three Phase 3 Hp
    (460 V AC) Three Phase 5 Hp
    (575 V AC) Three Phase 5 Hp
  • General Use Rating UL/CSA:
    (600 V AC) 28 A
  • Horsepower Rating UL/CSA:
    (120 V AC) Single Phase 1 hp
    (200 … 208 V AC) Three Phase 3 hp
    (220 … 240 V AC) Three Phase 3 hp
    (240 V AC) Single Phase 2 hp
    (440 … 480 V AC) Three Phase 7-1/2 hp
    (550 … 600 V AC) Three Phase 10 hp
  • Tightening Torque UL/CSA:
     Auxiliary Circuit 11 in·lb
    Control Circuit 11 in·lb
    Main Circuit 13 in·lb

Environmental

  • Ambient Air Temperature:
     Close to Contactor Fitted with Thermal O/L Relay -25 … 60 °C
    Close to Contactor without Thermal O/L Relay -40 … 70 °C
    Close to Contactor for Storage -60 … +80 °C
  • Climatic Withstand:
     Category B according to IEC 60947-1 Annex Q
  • Maximum Operating Altitude Permissible:
     Without Derating 3000 m

 

 